Explosion Protection Mark: [Exia]ⅡCⅡB Current Channel: Single Input/ Single Output, Single Input/ Double Outputs, Double Inputs/ Double Outputs
Transmission Precision: ± 0.1%FxS (25°C) Temperature Draft: < 50 ppm/°C
Allowable Input Signal for Hazardous Area Thermocouple: K, E, S, B, J, T, R, N Onput Signal to Safe Area Direct Current: 4...20 mA
Power Consumption (at 24 VCD Power Supply): 0.5 W, 0.8 W, 1.3 W    
Download:

● Transmits Single/Double Channel Thermocouple Signals or Voltage Signals from Haz. Areas

   by isolating/transmitting Output Single/Double Current or Voltage to Non-Haz. Areas

● It has a Cold Junction Temperature Compensation Function and can be connected to a

   Connection Network in a Non-Hazardous Area via communication Interface

● Intelligent Product with Online Self-Diagnosis Function

● Customer can set the Input Signal Type and Output Range with a Handheld Programmer

● Temperature Measurement Amplifier with Assembly and Disassembly Terminal

● Intrinsically Safe Input Loop EEx ia with Wire Breakage Monitoring Function
● Applied Area according to ATEX: II (1) GD
● Thermocouple Input, mV Signal
● Adjustable Output Analogue at Input Failure
● Current Output 4...20 mA
● Alarm Function only for Single Input Product (ECXI-43A)
● Built-In Temperature Compensating Resistor without an External Compensating Resistor